ETP-WM/E & ETP-WM/E24 Wall Mounts – Installation Instructions
Copyright 2010 Talk-A-Phone Co. All rights reserved.
Talk-A-Phone Co. • 7530 North Natchez Avenue • Niles, Illinois 60714-3804 Rev. 7/12/10
Phone 773.539.1100 • Fax 773.539.1241 • [email protected] • www.talkaphone.com
All prices and specifications are subject to change without notice.
Talk-A-Phone, Talk-A-Lert, Scream Alert and WEBS are registered trademarks of Talk-A-Phone Co.
I. Introduction
The Model ETP-WM/E and ETP-WM/E24 Wall Mount units are designed to house the Talk-A-Phone Blue
Light/Strobe and a Talk-A-Phone 400-Series or 500-Series ADA compliant hands-free Emergency Phone.
II. Installation
To install the Wall Mount after site preparation (including telephone/data line and provision of power for the Blue
Light/Strobe), follow these steps:
1. The Wall Mount is held to the wall with 4 #10 screws. Install two #10 screws in order to hold the top
section to the wall. Note that the screws should be located so that the Wall Mount will be at the
desired height and in the correct position to receive any conduit connections.
2. Electric power and the telephone/data line can be brought into the unit in one of two ways:
a. There are two large openings in the back of the unit to allow the unit to be mounted over a
standard flush-mounted electrical box and/or flush-mounted telephone connector box.
b. There are two conduit openings available on the bottom of the unit to feed the power and/or
telephone/data line inside the unit (Note: power and telephone/data lines cannot be ran in the
same conduit).
3. Remove the cap lid from the Wall Mount by removing the four #10 spanner security screws located
on the side of the unit. DO NOT remove the Lexan shield from the unit. Mount the unit on the wall
using the two keyholes on the top rear of the unit to the two screws mounted to the wall in step 1.
4. Install two additional #10 screws of the appropriate type in the holes in the lower rear of the unit.
Tighten all four screws.
5. Install conduit over the bottom hole(s) of the unit if method (b) is being used (see step 2) and bring
power line and/or telephone/data line inside the unit.
6. The 120VAC model ETP-EL (polycarbonate base) blue light strobe can be connected to the 120VAC
output voltage of the power source. If using the ETP-EL12/24 (polycarbonate base) blue light strobe,
connect the power cable to either the 12-24VDC or the 24VAC output voltage of the power source
(shown in Figure 1).
7. When using the Blue Light/Strobe with ETP-400 Series Emergency Phones, connect the orange and
black auxiliary control cable pair of the Blue Light/Strobe to the orange and black wires of the
Emergency Phone. Refer to the Emergency Phone Manual for information regarding the
programming of your phone.
When using the ETP-EL Series Blue Light/Strobe with VOIP-500 Series Emergency Phones, connect
the orange and black auxiliary control cable pair of the Blue Light/Strobe to positions 3 and 4 (Aux.
Output 2) of the 6-pin connector plug of the VOIP-500 Series Phone.